Automotive Technology
Industrial Technology
Information Technology
Railway Technology
Ship & Marine Technology
EMC
Environmental Simulation
Radio
Medical Technology
Avionic Technology
You are here: Home Industries Ship & Marine Technology Environmental Simulation
 

Ship & Marine - Environmental Simulation

 

As Phoenix Testlab has a great reputation to live up to, it pursues both innovation and quality for testing in the ship & marine sector. The environmental testing area was doubled in size in 2004 and is now used to test entire units and systems. Clients from all over the world appreciate our approach and competence in the field of environmental simulation.

The extension of the environmental laboratory illustrates that at Phoenix Testlab, comlete assmblies can be tested for vibration, temperature and sealing.

 

Accreditation/Certification

 

Accreditation: DIN EN ISO/IEC 17025 / DIN EN 45011
Certification: DIN EN ISO 9001 and DIN EN ISO 14001
Approval by: Federal German Maritime and Hydrographic Agency (BSH)

Phoenix Testlab cooperates with some of the most influential classification companies in the world such as GL (D), ABS (US), BV (F), DNV (N), LR (GB),
PRS (PL), NK (JP) and RINA (I) and performs EMC tests according to their standards. If your appliance fulfills the standards of the classification company of your choice, this company will finally certificate it.

 
   
 

Relevant standards include

 

  • DIN EN 60945 (Navigation and radio communication appliances)

    Basic standards:
  • DIN EN 60068-2-6 (Sinusoidal vibration testing)
  • DIN EN 60068-2-2 (Climatic testing)
  • DIN EN 60068-2-14 (Rapid temperature change testing)
  • DIN EN 60068-2-57 (Salt mist)
  • DIN EN 60529 (IP-code)

 
   
 

Laboratory equipment

 

  • Two electrodynamic vibration systems with
    superimposed climates (33.4 kN and 55 kN)
  • Three electrodynamic vibration systems with
    superimposed temperatures (55 kN up to 105 kN)
  • Electrodynamic vibration systems at an ambient
    temperature (21 kN)
  • Temperature and climatic chambers in combination
    with sunlight simulation: 0.5 m³ up to 19 m³,
    rate of change 1-10 K/min.
  • Shock chambers: air-air, option with defined climate:
    0.1 m³ up to 7 m³
  • Three salt mist chambers: 0.5 m³; 1 m³ and 11 m³
  • Dust and spray water chambers (IP code): 0.5 m³
    up to 11 m³
  • Two 4 K contaminant gas chambers
  • Flammability cabinet
  • Creeping current tester
  • High voltage, protective conductor and
    leakage current tester
  • Monitoring systems for controlling and
    monitoring test specimens

 
   
 

Monitoring equipment

 

  • Reproducible set-ups on pre-assembled vibration holders
  • Standardised measurement methods for recording analog data
  • Various bus monitoring systems such as LAN, Interbus, DeviceNet, Ethernet and Profibus

 
 

Contact

 

If you do not find what you are looking for, please contact our representatives who will be happy to help you.

Contact Person Sales Department

 
 
 
 
Quick Links
 
  Print this page
 
Search