Industrial Technology - Environmental Simulation |
 |
| |
Our engineers' expertise as well as the testing machinery in our environmental simulation laboratory are specially geared to extreme testing requirements. Climatic tests within a temperature range from -40°C to +180°C for volumes of up to 19,000 litres and vibration tests of control cabinets with weights of up to 0.5t - these are some of the boundary values of our facilities. We also perform vibration tests with climatic superposition in accordance with your demands.
Our tests will allow you to define the maximum limits of your products under reproducible environmental influences such as salt mist, vibration, climate, dust and water at Phoenix Testlab.
We can also combine the tests listed above with electrical safety tests to help you optimise your costs. |
 |
| |
Accreditation/Certification |
 |
| |
Accreditation: DIN EN ISO/IEC 17025 / DIN EN 45011 Certification: DIN EN ISO 9001 and DIN EN ISO 14001
|
| |
 |
 |
| |
|
| |
Relevant standards include |
 |
| |
|
- DIN EN 60068-2-6 (Sinusoidal vibration testing)
- DIN EN 60068-2-2 (Climatic testing)
- DIN EN 60068-2-14 (Rapid temperature change testing)
- DIN EN 60068-2-57 (Salt mist)
- DIN EN 60529 (IP-code)
|
| |
 |
 |
| |
|
| |
Environmental test laboratory equipment |
 |
| |
|
- Two electrodynamic vibration systems with
superimposed climates (33.4 kN and 55 kN)
- Three electrodynamic vibration systems with
superimposed temperatures (55 kN up to 105 kN)
- Electrodynamic vibration systems at ambient
temperature (21 kN)
- Temperature and climatic chambers in combination
with sunlight simulation: 0.5 m³ up to 19 m³, rate of change 1-10 K/min.
- Shock chambers: air-air, option with defined climate:
0.1 m³ up to 7 m³
- Three salt mist chambers: 0.5 m³; 1 m³ and 11 m³
- Dust and spray water chambers (IP code): 0.5 m³ up to
11 m³
- Two 4 K contaminant gas chambers
- Monitoring systems for controlling and monitoring
test speciments - Contact monitoring on several channels in the micro-second range - Operation devices, suitable for use in temperature and climate chambers - Electronic loads etc.
|
| |
 |
 |
| |
|
| |
Monitoring equipment |
 |
| |
|
- Reproducible set-ups on pre-assembled vibration holders
- Standardised measurement methods for recording analog data
- Various bus monitoring systems like LAN, Interbus, DeviceNet, Ethernet and Profibus
|
| |
| |
Contact |
 |
| |
If you do not find what you are looking for, please contact our representatives who will be happy to help you.
Contact Person Sales Department
|
| |
|
|