Automotive Technology - EMC |
 |
| |
Phoenix Testlab is a modern EMC test laboratory for electronic components which are used in motor vehicles. Increasingly complex qualification tests need to be performed while development cycles are shortening.
Operation and monitoring of increasingly complex components are tasks which we tackle successfully to meet the wishes and demands of our customers with our highly motivated team. |
 |
| |
Accreditation/Certification |
 |
| |
Accreditation: DIN EN ISO/IEC 17025 / DIN EN 45011 Certification: DIN EN ISO 9001 and DIN EN ISO 14001
- Accredited (e1/E1) as technical service for the Federal German Motor Transport Authority (Kraftfahrtbundesamt/KBA) for tests in accordance with directive 2009/19/EC (component tests) and ECE Regulation 10, Rev. 3(component tests)
- Accredited for the entire range of EMC in accordance with the Automotive EMC Laboratory Accreditation Program (AEMCLAP)
- Approved by Ford, General Motors and Chrysler
|
| |
 |
 |
| |
|
| |
Relevant standards include |
 |
| |
|
- ISO 11452-X (Immunity to interference procedure (TEM cell, stripline, BCI, anechoic chamber))
- ISO 10605 (Testing of immunity to interference against electrostatic discharge)
- CISPR 25 (Measurement of radiated and conducted interferences emissions)
- ISO 7637 (On-board power supply simulation; testing of immunity to interference from impulses)
- BMW GS 95002 (EMC requirements of BMW)
- GMW 3097 (EMC requirements of General Motors)
- VW 80101
- Ford ES-XW7T-1A278-AC/-AB (EMC requirements of Ford)
- MBN 10284 (EMC requirements of Mercedes)
- DC 10614 (EMC requirements of Daimler Chrysler),
DC 10615 (Electrical system performance requirements for components of Daimler Chrysler)
- ISO 16750 (General requirements for motor vehicle components)
|
| |
 |
 |
| |
|
| |
EMC test laboratory equipment |
 |
| |
|
- Five anechoic chambers
- Measurement distances of 3 m/5 m - Emission measurement up to 110 GHz - Field strength of up to 600 V/m (up to 18 GHz)
- Open area test site with a 10 m measurement distance
- Conducted radio disturbance emission and immunity in the screened chamber
- Automotive impulse test sites
- ESD testing up to 30 kV
- Bulk current injection (BCI)
- Stripline, triplate, TEM cell
- Optical fibre interfaces for various bus systems
- Standardised measuring methods for the acquisition of analog measuring values
- Simulators for GSM, UMTS, Bluetooth and GPS
- Acoustic analysers
|
| |
| |
Contact |
 |
| |
If you do not find what you are looking for, please contact our representatives who will be happy to help you.
Contact Person Sales Department
|
| |
|
|